Store finder

Back
X
Selection
AKM1-20
Moulded Case Circuit Breaker 3P,20A,Ir=(0,8-1,0)In, 400/415V, 50/60Hz, Icu=36kA, Ics=25kA
Net67.96053 EUR
Gross86.30987 EUR
More than 1 pc(s) in stock
Rated permanent current Iu
20 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36 kA
Overload release current setting
16 -20 A
AKM1-32
Moulded Case Circuit Breaker 3P,32A,Ir=(0,8-1,0)In, 400/415V, 50/60Hz, Icu=36kA, Ics=25kA
Net67.96053 EUR
Gross86.30987 EUR
1 pc(s) in stock
Rated permanent current Iu
32 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36 kA
Overload release current setting
25.6 -32 A
AKM1-40
Moulded Case Circuit Breaker 3P,40A,Ir=(0,8-1,0)In, 400/415V, 50/60Hz, Icu=36kA, Ics=25kA
Net67.96053 EUR
Gross86.30987 EUR
More than 1 pc(s) in stock
Rated permanent current Iu
40 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36 kA
Overload release current setting
32 -40 A
AKM1-63
Moulded Case Circuit Breaker 3P,63A,Ir=(0,8-1,0)In, 400/415V, 50/60Hz, Icu=36kA, Ics=25kA
Net67.96053 EUR
Gross86.30987 EUR
More than 1 pc(s) in stock
Rated permanent current Iu
63 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36 kA
Overload release current setting
50.4 -63 A
AKM1-80
Moulded Case Circuit Breaker 3P,80A,Ir=(0,8-1,0)In, 400/415V, 50/60Hz, Icu=36kA, Ics=25kA
Net67.96053 EUR
Gross86.30987 EUR
Ordering in process: 11/23/24
Rated permanent current Iu
80 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36 kA
Overload release current setting
64 -80 A
AKM1-125
Moulded Case Circuit Breaker 3P,125A,Ir=(0,8-1,0)In,400/415V, 50/60Hz, Icu=36kA, Ics=25kA
Net67.96053 EUR
Gross86.30987 EUR
More than 5 pc(s) in stock
Rated permanent current Iu
125 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36 kA
Overload release current setting
100 -125 A
AKM1-160
Moulded Case Circuit Breaker 3P,160A,Ir=(0,8-1,0)In,400/415V, 50/60Hz, Icu=36kA, Ics=25kA
Net73.36842 EUR
Gross93.17789 EUR
More than 5 pc(s) in stock
Rated permanent current Iu
160 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36 kA
Overload release current setting
128 -160 A
AKM2-180
Moulded Case Circuit Breaker 3P,180A,Ir=(0,8-1,0)In,400/415V, 50/60Hz, Icu=36kA, Ics=25kA
Net105.53947 EUR
Gross134.03513 EUR
More than 5 pc(s) in stock
Rated permanent current Iu
180 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36 kA
Overload release current setting
144 -180 A
AKM2-250
Moulded Case Circuit Breaker 3P,250A,Ir=(0,8-1,0)In,400/415V, 50/60Hz, Icu=36kA, Ics=25kA
Net105.53947 EUR
Gross134.03513 EUR
More than 10 pc(s) in stock
Rated permanent current Iu
250 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36 kA
Overload release current setting
200 -250 A
AKM3-400
Moulded Case Circuit Breaker 3P,400A,Ir=(0,8-1,0)In,400/415V, 50/60Hz, Icu=50kA, Ics=35kA
Net218.13158 EUR
Gross277.02711 EUR
More than 5 pc(s) in stock
Rated permanent current Iu
400 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50 kA
Overload release current setting
320 -400 A
AKM4-630
Moulded Case Circuit Breaker 3P,630A,Ir=(0,8-1,0)In,400/415V, 50/60Hz, Icu=50kA, Ics=35kA
Net283.89474 EUR
Gross360.54632 EUR
More than 1 pc(s) in stock
Rated permanent current Iu
630 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50 kA
Overload release current setting
504 -630 A
New product
AKMN1-160
Moulded case circuit breaker 4P,160A,Ir=(0,8-1,0)In,400/415V, 50/60Hz, Icu=36kA, Ics=25kA
Net87.89474 EUR
Gross111.62632 EUR
Ordering in process: 11/23/24
Rated permanent current Iu
160 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25 kA
Overload release current setting
128 -160 A
New product
AKMN2-250
Moulded case circuit breaker 4P,250A,Ir=(0,8-1,0)In,400/415V, 50/60Hz, Icu=36kA, Ics=25kA
Net127.32895 EUR
Gross161.70777 EUR
Ordering in process: 1/15/25
Rated permanent current Iu
250 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25 kA
Overload release current setting
200 -250 A
New product
AKMN3-400
Moulded case circuit breaker 4P,400A,Ir=(0,8-1,0)In,400/415V, 50/60Hz, Icu=50kA, Ics=35kA
Net263.09211 EUR
Gross334.12698 EUR
Ordering in process: 1/15/25
Rated permanent current Iu
400 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25 kA
Overload release current setting
320 -400 A
New product
AKMN4-630
Moulded case circuit breaker 4P,630A,Ir=(0,8-1,0)In,400/415V, 50/60Hz, Icu=50kA, Ics=35kA
Net352.25000 EUR
Gross447.35750 EUR
5 pc(s) in stock
Rated permanent current Iu
630 A
Rated voltage
380 -420 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25 kA
Overload release current setting
504 -630 A