EVOAG residual current circuit breaker

Residual current breaker, 2 poles
25A, 30mA, 10kA, A
Net47.38158 EUR
Gross60.17461 EUR
More than 20 pc(s) in stock
Rated voltage
230 V
Rated current
25 A
Rated fault current
0.03 A
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV

Residual current breaker, 2 poles
40A, 30mA, 10kA, A
Net47.38158 EUR
Gross60.17461 EUR
More than 20 pc(s) in stock
Rated voltage
230 V
Rated current
40 A
Rated fault current
0.03 A
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV

Residual current breaker, 2 poles
63A, 30mA, 10kA, A
Net47.38158 EUR
Gross60.17461 EUR
More than 20 pc(s) in stock
Rated voltage
230 V
Rated current
63 A
Rated fault current
0.03 A
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV

Residual current breaker, 2 poles
80A, 30mA, 10kA, A
Net53.92105 EUR
Gross68.47973 EUR
Out of stock
Rated voltage
230 V
Rated current
80 A
Rated fault current
0.03 A
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV

Residual current breaker, 2 poles
100A, 30mA, 10kA, A
Net67.00000 EUR
Gross85.09000 EUR
More than 20 pc(s) in stock
Rated voltage
230 V
Rated current
100 A
Rated fault current
0.03 A
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV

Residual current breaker, 4 poles
25A, 30mA, 10kA, A
Net60.65789 EUR
Gross77.03552 EUR
More than 20 pc(s) in stock
Rated voltage
400 V
Rated current
25 A
Rated fault current
0.03 A
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV

Residual current breaker, 4 poles
40A, 30mA, 10kA, A
Net60.65789 EUR
Gross77.03552 EUR
More than 20 pc(s) in stock
Rated voltage
400 V
Rated current
40 A
Rated fault current
0.03 A
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV

Residual current breaker, 4 poles
63A, 30mA, 10kA, A
Net60.65789 EUR
Gross77.03552 EUR
More than 20 pc(s) in stock
Rated voltage
400 V
Rated current
63 A
Rated fault current
0.03 A
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV

Residual current breaker, 4 poles
80A, 30mA, 10kA, A
Net67.18421 EUR
Gross85.32395 EUR
More than 20 pc(s) in stock
Rated voltage
400 V
Rated current
80 A
Rated fault current
0.03 A
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV

Residual current breaker, 4 poles
100A, 30mA, 10kA, A
Net80.26316 EUR
Gross101.93421 EUR
More than 20 pc(s) in stock
Rated voltage
400 V
Rated current
100 A
Rated fault current
0.03 A
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV