Product datasheet - KVKVB-32/03

Residual current circuit breaker, 2P, 1 module, B char.
32A, 30mA, 10kA, AC, E3
Item number:KVKVB-32/03
(EAN: 5997374163125)
32A, 30mA, 10kA, AC, E3
Residual current circuit breaker, 2P, 1 module, B char.
Item number:KVKVB-32/03 (EAN: 5997374163125)Technical data 32A, 30mA, 10kA, AC, E3
4 pc(s) in stock
Net
26.42105 EUR
26.42105 EUR
Gross
33.55473 EUR
Number of poles (total):
2
Number of protected poles:
1
Rated voltage:
230 V
Rated insulation voltage Ui:
690 V
Rated impulse withstand voltage Uimp:
4 kV
Rated fault current:
0.03 A
Leakage current type:
AC
Current limiting class:
3
Voltage type:
AC
Frequency:
50/60 Hz
Release characteristic:
B
Ambient temperature during operating:
-25 -55 °C
Flush-mounted installation:
Yes
Degree of protection (IP):
IP20
Connectable conductor cross section solid-core:
1.5 -10 mm²
Connectable conductor cross section multi-wired:
1.5 -10 mm²
Warranty:
2 year
The combined protective switch is mainly used in electrical installations of buildings, for personal, overload and short circuit protection. It is especially suitable for electrical protection of rooms with increased safety requirements. The current transformer of the protective switch, namely the magnetic quick breaker and the bimetallic, thermal, residual current breaker are placed in the same box. It breaks the circuit of the protected device only in one pole. The device is equipped with optical display for signaling the operational state: the red color marks the “ON” state of the switch. Correct operation of the device can be controlled by pushing the “T” test button. The test should possibly be effected monthly.
![]() |
![]() |
|
![]() |
Installation
|
![]() |
Related products
Similar items

Residual Current Circuit Breaker, Overcurrent Protect. 2P,B
32A, 30 mA, 6kA, AC
Net36.09211 EUR
Gross45.83698 EUR
Ordering in process: 5/9/25
Number of poles (total)
2
Number of protected poles
1
Rated voltage
230 V
Rated insulation voltage Ui
690 V
Rated impulse withstand voltage Uimp
4 kV

Residual current circuit breaker, electr., 2P, 1 mod, B kar.
B32, 30mA, 6kA, AC, E3
Net33.61842 EUR
Gross42.69539 EUR
More than 5 pc(s) in stock
Number of poles (total)
2
Number of protected poles
1
Rated voltage
230 V
Rated insulation voltage Ui
690 V
Rated impulse withstand voltage Uimp
4 kV
Recently viewed products

Heat shrink tube, thin wall, 2:1 ratio, green
50,8/25,4mm, POLIOLEFIN
Net8.89474 EUR
Gross11.29632 EUR
More than 50 pc(s) in stock
Type
Heat-shrink
Model
Thin-walled
Shrink rate
2:1
Inner diameter before heat-shrink
50.8 mm
Inner diameter after heat-shrink
25.4 mm

Heat shrink tube, thin wall, 2:1 ratio, red
9,5/4,8mm, POLIOLEFIN
Net1.46053 EUR
Gross1.85487 EUR
More than 1000 pc(s) in stock
Type
Heat-shrink
Model
Thin-walled
Shrink rate
2:1
Inner diameter before heat-shrink
9.5 mm
Inner diameter after heat-shrink
4.8 mm

Heat shrink tube, thin wall, 2:1 ratio, grey, on reel
1,6/0,8mm, POLIOLEFIN
Net0.94395 EUR
Gross1.19882 EUR
More than 200 pc(s) in stock
Type
Heat-shrink
Model
Thin-walled
Shrink rate
2:1
Inner diameter before heat-shrink
1.6 mm
Inner diameter after heat-shrink
0.8 mm

Fuse-switch-disconnect,busbar,horizont,cable top,flat ter
AC 400V, 630A, 100 kA; AC 690V, 500A, 50 kA; 3P,NH3,60mm,M12
Net315.48684 EUR
Gross400.66829 EUR
1 pc(s) in stock
Equipment fuse switch disconnector housing
With safety switch disconnector
Rated operation current Ie
630 A
Max. rated operation voltage Ue AC
690 V
Rated insulation voltage Ui
800 V
Construction size fuse inserts
NH3

Flexible terminal stripe, H shape, push plate, 12 bl., black
25mm2, 450VAC, 80A, PP
Net12.47368 EUR
Gross15.84157 EUR
More than 100 pc(s) in stock
Drill hole distance centrically
16 mm
Connectable conductor cross section fine-strand without cable end sleeve
4 -26 mm²
Connectable conductor cross section fine-strand with cable end sleeve
4 -25 mm²
Connectable conductor cross section solid-core
4 -25 mm²